The Vape-Jet needle will need to be changed if it is bent during filling, or if a batch of cartridges being filled require a different needle length than the previous batch.
Step-by-step guide
Needed tools:
Needle-nose pliers
Needed materials:
New injection needle
Procedure:
Remove the old injection needle by gripping the needle luer-lock base with the needle-nose pliers and twisting counterclockwise (if viewing up the needle from the Vape-Jet base).
Select the appropriate length of new injection needle.
Grip the luer-lock base of the new injection needle with the needle-nose pliers, and insert into the luer-lock of the needle holder; gently twist clockwise 1/4 turn to secure the new injection needle.